Parameters |
|
Ratings D |
|
|
|
Max Operational Depth Pressure Balanced |
|
4000 m (6,000 psi) |
|
|
|
Maximum Operational
Differential Pressure
|
|
|
Receptacle |
|
Plug |
|
|
12-way Nautilus |
224bar (3250psi) |
|
303bar (4400psi) |
Operational Temperature |
|
Seawater |
-5°C to +40°C |
|
(23°F to 104°F) |
|
|
Air |
-20°C to +50°C |
|
(-4°F to 122°F) |
Storage Temperature |
|
|
-30°C to +60° C |
|
(-22°F to 140°F) |
Subsea Mate/De-mate Cycles |
|
1000 total cycles maximum after factory testing
200 cycles maximum in turbid seawater conditions
|
|
|
|
Maximum Mate/De-mate Force |
|
< 500N (112 lb-f) |
|
|
|
Minimum Force Needed to De-mate |
|
98N (22 lb-f) |
|
|
|
Configurations |
|
ROV, Stab & Diver-Mate |
|
|
|
Material |
|
Shell & Latch Fingers |
Titanium & High Strength Stainless Steel |
|
|
|
|
Boots & Bladders |
Teledyne Proprietary Plastic & Rubber Components |
|
|
|
|
Slides (ROV Only) |
Titanium, Acetal, or Delrin |
|
|
|
|
Repeater Housing |
Titanium |
|
|
Design Life |
|
30 Years (Assuming Operational Temperature of 4°C) |
|
|
|
Number of Circuits |
|
4,7,12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power Wires (Pass Through) |
Maximum Operational Current per Circuit |
|
3 Amps |
|
|
|
Maximum Operational Voltage |
|
620 VAC Phase to Ground |
|
|
|
Insulation Resistance |
|
≥ 10 GΩ @ 1 KVDC |
|
|
Power Wires (Required to run Repeater) |
Operating Power |
|
5 watts |
|
|
|
Operating Voltages |
|
24 Volts +12/-16 Volts |
|
|
|
Max In Rush Power |
|
10 watts |
|
|
Contact Resistance |
|
≤ 10 mΩ per contact |
|
|
|
Mated Connector Continuity Resistance |
|
≤ 0.2 Ω per contact |
|
|
|
Fully Compatible Materials |
|
Fresh Water, Sea Water, DC 200 Silicone Oil |
|
|
|
Intermittently Compatible Materials |
|
MEG, Oceanic HW 443, 50% Citric Acid, 50% Acetic Acid |
|
|
|
Max Length
(Dependent on customer equipment)
|
|
|
|
|
|
|
|
2 Housings |
|
*5 KM (Dependent on Power loss) |
|