General Specifications |
|
Metal Loss measurements
|
Erosion |
Design life |
>25 years |
Design pressure |
10KSI or 15KSI* |
Hydrostatic test pressure |
Design pressure x 1.5 |
Design temperature range ** |
-40 to 177°C |
Ambient operating temperature |
-20 to 70°C |
Design depth |
3000m |
Hyperbaric test pressure |
450bar |
Paint options |
Standard sensor is unpainted. Optional Norsok M-501 System 7 paint system available. |
Design codes and standards |
API 6A / 17D, ASME IX, API 17F, |
NACE MR-0175, all process wetted material supplied with 3.1 traceable certification |
|
|
|
|
|
|
|
CEION ® Measurement |
|
Sensing element |
Spark eroded spiral |
Element material |
Inconel 625 |
Element thickness |
6mm angled; 8mm flush |
Element life |
5mm angled; 7 mm flush |
Resolution |
45nm |
|
|
|
|
Mechanical Specification |
|
Mechanical interface |
API 6A 2 1/16 |
Seal groove |
BX152 |
Approx weight in air |
23kg (add 4 kg for 15K) (Probe weight only) |
Flange material |
10K: Duplex UNS S31803 with Inconel 625 UNS N06625 cladding in process wetted area |
|
15K: Super Duplex UNS S32760 with Inconel 625 UNS N06625 cladding in process wetted area |
|
|
Electronics Housing material |
316L SS |
Jumper Interface |
Omnitec Mk2 |
Primary and Secondary |
|
Penetrators |
Glass-to-Metal, Inconel 625 (EB welded) |
Probe Neck Material |
Inconel 625 |
Termination Shell material |
316L SS |
Probe diameter |
50mm |
Probe length |
Selectable between 100 and 300mm |
Electrical Specification |
|
Supply Voltage |
24VDC (18V min, 30V max) |
Current consumption |
<50mA @24VDC |
In-rush |
120% max operating current for 500ms |
Output signal |
CANbus (CiA443, SIIS Level 2) or Modbus (RS485)
|